Step II (In Amesim)

 

Step to design the hydraulic system

1.  Run the Amesim program.

2.  Create an Interface block, as following funtion: “Menu>Modeling>Interface block>Create interface icon…”.

3.  Set the Interface icon

     Select a type of interface as RecurDynCosim. And then, set the number of inputs and outputs.

4.  Build a hydraulic system model.

 

Compile the Amesim model

1.  Select “Tools > Options > Amesim Preferences > Compilation“. And then, change the compiler as following dialog box.

     Note: The compilers should be installed additionally.

Note: It is needed to execute “Modeling > Check submodels…” for the Amesim model made in the old version of Amesim.

 

2.  Changes the mode into Parameter mode, the DLL file are generated in the same folder of Amesim model.

 

Note

When the user closes Amesim, “model_name_.dll” file would disappeared. So, during simulation in RecurDyn, do not close Amesim.

If the user wants to extract “model_name_.dll”, uses the AMELoad.exe installed in the “win32” directory of the Amesim installation.

If the user’s system name is “test1.ame”, type “AMELoad test1” in a CMD window in the directory where the Amesim model is located