Figure 1 Parameter for Frequency Response analysis
|
Parameter |
FRAPara command | ||||
|
Max number of mode |
Amplitude Factor |
Animation Frame |
Including damping (Damped/ |
Logarithmic Step |
FRAPARA/MAXMODE=10, AMP=1.0, CYCL=30, DAMP=TRUE, LOGSTEP=FALSE |
•FRAPARA: Parameter for Frequency Response analysis
•MAXMODE: Max. no. of modes
•AMP: Amplitude Factor
•CYCL: Animation Frame
•DAMP
•“DAMP=FALSE” means undamped frequency response analysis without damping matrix.
•“DAMP=TRUE” means damped frequency response analysis with damping matrix.
•LOGSTEP
•“LOGSTEP=FALSE” means frequency response analysis without Logarithmic Step.
•“LOGSTEP =TRUE” means frequency response analysis with Logarithmic Step.
Note
This command is frequency response analysis option
You must define the FRAParameter command prior to the Frequency Response Analysis command