Figure 1 Parameter for Frequency Response analysis
Parameter |
FRAPara command | ||||
Max number of mode |
Amplitude Factor |
Animation Frame |
Including damping (Damped/ |
Logarithmic Step |
FRAPARA/MAXMODE=10, AMP=1.0, CYCL=30, DAMP=TRUE, LOGSTEP=FALSE |
• FRAPARA: Parameter for Frequency Response analysis
• MAXMODE: Max. no. of modes
• AMP: Amplitude Factor
• CYCL: Animation Frame
• DAMP
• “DAMP=FALSE” means undamped frequency response analysis without damping matrix.
• “DAMP=TRUE” means damped frequency response analysis with damping matrix.
• LOGSTEP
• “LOGSTEP=FALSE” means frequency response analysis without Logarithmic Step.
• “LOGSTEP =TRUE” means frequency response analysis with Logarithmic Step.
Note
This command is frequency response analysis option
You must define the FRAParameter command prior to the Frequency Response Analysis command